[ros-dev] CodePage Reg Key Error at Boot
Hartmut Birr
osexpert at googlemail.com
Wed Nov 9 21:42:18 CET 2005
Ge van Geldorp wrote:
> Not sure if this is the cause of the problem, but I just fixed a memory
> overwrite (r19068) which could potentially have caused the in-memory copy of
> the registry to be corrupted. If this corrupt copy was then written out to
> disk you could get that error message during the next boot. Again, not sure
> if this was the cause of the problem (I can't reproduce the original
> problem), but the time frame seems to fit.
>
>
> GvG
It didn't solve the problem. I get the error again. The difference is,
that is now an other key which reports the error. I've also removed some
entries for my GB-NIC in hivesys.inf.
UNKNOWN: (boot\freeldr\freeldr\reactos\binhive.c:1506) Name:
\\Registry\Machine\SYSTEM\ControlSet001\Control\Class
UNKNOWN: (boot\freeldr\freeldr\reactos\binhive.c:1510) Class
UNKNOWN: (boot\freeldr\freeldr\reactos\binhive.c:1511) Invalid key cell id!
UNKNOWN: (boot\freeldr\freeldr\reactos\binhive.c:1512) "KeyCell->Id 0,
REG_KEY_CELL_ID 6b6e, KeyCell->CellSize 0
UNKNOWN means DEBUG_HB ;-) . On an unmodified source, it fails on line
#1481 in binhive.c.
- Hartmut
More information about the Ros-dev
mailing list